A customer wants to verify that all the memory DIMMs in a ProLiant Gen8 server are genuine HP. What will provide this information?
A. Windows Event Viewer
B. ROM Based Setup Utility (RBSU]
C. iLO Event Log
D. SmartMemory
Which statements are correct about the HP Customer Self Repair (CSR) program?
A. A travel and labor charge applies when customers request HP to replace parts.
B. A travel and labor charge does not apply when customers decline to replace a mandatory CSR part.
C. A travel and labor charge does not apply when customers decline to replace an optional CSR part.
D. A travel and labor charge applies when customers decline to replace an optional CSR part.
Why is it considered a best practice to use tools such as HP Smart Update Manager (SUM) and Virtual Connect Support Utility (VCSU) to deploy firmware components?
A. These tools are compatible with all versions of firmware
B. These tools check dependencies and limitations.
C. These are the only tools that work with Virtual Connect Enterprise Utility (VCEU).
D. These tools support cross-platform deployments
What is required by iLO to support agentless management? (Select two)
A. Write Community
B. System Location
C. SNMP Alert Destination
D. Read Community
E. Trap Community
You cannot get to the network from any of the server blades in a c7000 enclosure with 10GbE Pass-Thru modules.
What should you verify first for proper connectivity to the network?
A. Correct SFPs are installed
B. External switch supports at least Gigabit speed
C. Interconnect link between the Pass-Thru modules
D. External switch set to half duplex
Which statements are correct about the HP Customer Self Repair (CSR) program? (Select two.)
A. A travel and labor charge applies when customers decline to replace an optional CSR part.
B. A travel and labor charge does not apply when customers decline to replace an optional CSR part.
C. A travel and labor charge does not apply when customers decline to replace a mandatory CSR part.
D. A travel and labor charge applies when customers decline to replace a mandatory CSR part.
What should an administrator do to prevent discharge of static electricity when replacing components in a ProLiant server? (Select two.)
A. Place the server blade on a flat, level surface.
B. Wear a plastic grounding strap to remove the ESD-sensitive component from the static safe container
C. Place the ESD-sensitive component on a grounded surface.
D. Wear a cloth grounding strap to replace the defective component.
E. Avoid hand contact with the ESD-sensitive component by transporting in a static-safe container.
Which steps should you perform to save a Virtual Connect configuration?
A. From CLI show all > cfg.txt
B. Enclosure setting configuration scripts show, config save
C. Enclosure setting configuration scripts inventory
D. VCM Tools Backup/Restore Domain Configuration
Which hardware-based system security feature can securely store information such as passwords and encryption keys and can be used to authenticate the platform?
A. DHCP
B. RBSU
C. ORCA
D. TPM
An HP P421/1GBFBWC controller with three hard disks is configured as RAID 5. What is the minimum requirement to upgrade the disk configuration to RAID 60? (Select two.)
A. Five more hard disks
B. Three more hard disks
C. Smart Array Advanced Pack 2.0
D. BBWC