A network architect is designing a wireless solution for a company that is leasing one floor in a multi- floor building in a downtown area. The customer is concerned about ensuring complete Wi-Fi coverage and pin-pointing RF hazards.
What type of survey should the network architect perform?
A. Active
B. Virtual
C. Passive
D. Spectrum clearing
A customer has some employees that travel to various locations, where these employees will need Wi-Fi access at these locations. Because many of these locations do not have wireless support, the employees will need to carry an AP
solution with them. Internet connectivity, if it doesn't exist at these locations, will be provided by a national phone company USB wireless card which will be connected to AP. The wireless solution needs minimal bandwidth, but needs to
minimally support 802.1 lac wave 1 devices.
Which Aruba AP wireless solution would meet the needs of these employees most effectively and cost efficiently?
A. 318
B. 303H
C. 365
D. 203R
NewStellar has a main corporate campus in a business park with two adjacent buildings. Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total. The ceiling for each floor is 12 feet (3.6 meters) high with a dro This floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet (870 square meters). Assuming that wireless coverage is not required in the central area, which square footage (square meter) value should a network architect use when determining the number of APs in a capacity design for each floor?

A. 55.750 square feet {5,175 square meters)
B. 56.350 square feet {5,235 square meters)
C. 47.000 square feet {4,365 square meters)
D. 338,100 feet {31,410 square meters)
A network architect is redesigning a wireless network. The architect begins by analyzing the number of spatial streams supported by APs of various vendors as well as the wireless devices currently in the network, if the company wants to ensure that new wireless design, including user wireless devices, support Multi-User MIMO (MU-MIMO). Which standard or standards must the wireless products support?
A. Only 802.11ax and 8011.ac
B. Only 802.11ax
C. Only 802.11ax,802.1lac, and 802.l1n
D. Only 802.11ax,802.11ac, 802.11n, and 802.11a
A network architect is creating a new wired design for a warehouse building. As a best practice, what length should the architect allow for the service loop in the wiring closets in this environment?
A. 3-10 feet (1-3 m)
B. 3 feet (1 m)
C. 15-30 feet (5-10 m)
D. 30-60 feet (10-20 m)
A network architect imports a floorplan defined in a PNG file format. What is the function of the measurement tool in Aruba's VisualRF?
A. Define the appropriate dimensions of each object in a Floorplan View
B. Define the appropriate dimensions of a Floorplan and Building View
C. Define the appropriate dimensions of a Floorplan View
D. Define the appropriate dimensions of each room in a Floorplan View
A network architect plans to use two ArubaOS 5406 switches in a wiring closet configured in a VSF domain The VSF link requires a 40 GDps connection. Which SFP+ transceiver solutions would meet this requirement?
A. QSFP+ LC
B. SFP
C. SmartRate
D. QSFP28
A company is installing Internet of Things (loT) devices to support a smart and energy-efficient environment for a building, including loT devices for heating and air conditioning, lights, and window shades. loT devices of these types are typically classified as which category of devices?
A. Nomadic devices
B. Somewhat mobile devices (SMD)
C. Highly mobile devices (HMD)
D. Stationary devices
A network architect is designing a new wired and wireless solution for for a company. The company has two buildings on a campus, which each building has three floors. The campus core will be placed in the basement of Building 1. Each wiring closet has eight strands of multi-mode OM3 grade fiber that connect to a wiring closet of the first floor of the building it is contained, referred to as a main distribution frame (MDF). The maximum distance between a floor's wiring closet and the MDF is 100 feet (30 meters). The maximum distance between the two MDFs and the campus core is no more than 150 feet (45 meters). There are eight strands of multi-mode OM3 grade fiber from these two MDF closets to the campus core. Based on this information, which type of design should be used and what is the maximum speeds supported all uplinks for the existing the multi-mode fiber?
A. three-tier and 10 Gbps
B. three-tier and 40 Gbps
C. two-tier and 10 Gbps
D. two-tier and 40 Gbps
A customer is designing a new wired network. The customer requires 50 Gbps uplinks, VSF logical switching, and smart rate port support.
Which of the following switches would meet these requirements?
A. 3810M series
B. 6300 series
C. 5400R series
D. 8300 series