When you replace a motherboard, which step will completely test the newly installed component?
A. From ONTAP, execute sldiag.
B. From the LOADER prompt, type boot_ontap maint, then execute sldiag.
C. From the LOADER prompt, type boot_diags, then execute sldiag.
D. From the LOADER prompt, execute sldiag.
You have a 4-node MetroCluster system. A node needs to be taken down for maintenance, but all data needs to remain online.
In this scenario, what should you do to bring down a single node?
A. Perform an HA takeover of the node.
B. Perform a MetroCluster switchover.
C. Disable HA on each side of the MetroCluster.
D. Perform an aggregate relocation of the CFO aggregates on the node.
Which two statements describe ONTAP NVRAM? (Choose two.)
A. ONTAP NVRAM is used as read cache.
B. ONTAP NVRAM stores uncommitted writes.
C. ONTAP NVRAM is used as write cache.
D. ONTAP NVRAM is battery backed.
When using NetApp Volume Encryption (NVE) which type of server is needed to keep encryption keys separate from encrypted data?
A. KMIP
B. RADIUS
C. TLS
D. TKIP
Test user "LAB\tester" can perform an operation in the CIFS share "HR" from the SVM "svm1". However, the rest of the users from the HR department cannot perform the same operation. You want to determine why only "LAB\tester" can perform the operation.
In this scenario, which security trace filter accomplishes this task?
A. vserver security trace filter create -vserver svm1 -index 1 -protocol nfs -unix-name tester -trace-allow no
B. vserver security trace filter create -vserver svm1 -index 1 -protocol cifs -windows- name LAB\tester trace-allow no
C. vserver security trace filter create -vserver svm1 -index 1 -protocol cifs -windows- name LAB\tester trace-allow yes
D. vserver security trace filter create -vserver svm1 -index 1 -protocol nfs -unix-name tester -trace-allow yes
A customer asks what is the correct way to configure an ONTAP system for multi-tenancy. The customer wants to serve data and also protect data using SnapMirror from tenant A using network A and from tenant B using network B.
In this scenario, which statement is correct?
A. The customer must use different VLANs for the two tenants.
B. This setup can only work if tenant A and tenant B use a shared network infrastructure.
C. The customer must set up two different IPspaces for the two tenants.
D. Each node can only communicate with tenant A or tenant B, but not with both at the same time.
While troubleshooting client access issues to a CIFS share, you notice that the issue only occurs when the data LIF that the clients are accessing is on a specific node in the cluster.
In this scenario, which configuration should you review to determine why this issue is happening?
A. cluster health
B. Kerberos
C. share path
D. export policies
Source Path Destination Path Relationship ID Relationship Type msgld: msragld: 78e304e0-9781-1234-abcd-00a098d771bd XDP msxpgld: msraxpgld: 3ca42ab4-9782-1234-abcd-00a098d771bd XDP na_docavgld: ndradocavgld: a4b233b2-9783-1234-abcd-00a098d771bd XDP na_dr: ndradr: c97d36a0-6d7c-11e8-83fb-00a098d771bd XDP na_gld: ndragld: 9e7e034d-9782-1234-abcd-00a098d771bd XDP na_mpgld: ndrampgld: 16e52e0d-9783-1234-abcd-00a098d771bd XDP na_opengld: ndraopengld: dabb1813-9780-1234-abcd-00a098d771bd XDP na_poc: ndrapoc: c1d632d7-977b-1234-abcd-00a098d771bd XDP na_pubgld: ndrapubgld: 1a3f866c-9780-1234-abcd-00a098d771bd XDP
Referring to the output, which type of SnapMirror destination relationship is being used?
A. Single Volume SnapMirror Asynchronous
B. Single Volume SnapMirror Synchronous
C. SnapVault
D. Storage Virtual Machine DR
For testing purposes, your customer decides to use FC on a single-node ONTAP cluster. There is only one host that the customer expects to use. High availability is not a concern for this test. The customer connects the host directly to the ONTAP node. The LUN is set up, and the igroup is configured. When the customer tries to attach to the LUN from the host, the LUN is not seen by the host.
Which statement is correct in this scenario?
A. Multipathing must be used and connected to another FC path.
B. NPV must be enabled on the host before trying to attach to the LUN.
C. NPIV must be enabled on the host before trying to attach to the LUN.
D. An FC switch must be used with ONTAP.