Exhibit.

You are working on a project to install a new AFF A300 storage array. You use a pair of Nexus 3596 switches for FC connectivity between your VMware ESXi servers and the AFF A300. Which SAN switch feature must be enabled to accomplish this task?
A. N_Port ID visualization (NP1V)
B. Open Shortest Path First (OSPF)
C. Link Aggregation Control Protocol (LACP)
D. N_Port Visualization (NPV)
You have a 4-node cluster with a FAS8200 HA pair and an AFF A300 HA pair. You need to migrate a LUN from a FAS8200 node to an AFF A300 node for faster performance. Which method will non-disruptively migrate the LUN to the AFF A300 while retaining snapshots of the LUN on the FAS8200?
A. You move the LUN.
B. You relocate the aggregate.
C. You move the volume.
D. You copy the LUN.
You must relocate a LUN from one AFF A700 HA pair to another AFF A300 HA pair while preserving all storage efficiencies. What are two ways to accomplish this task? (Choose two.)
A. Copy the volume.
B. Copy the LUN.
C. Move the volume.
D. Move the LUN.
A4-node ONTAP FAS9000 cluster was used to serve I/O from six RedHat 7.3 servers. The servers were
configured with maximum, queue depth.
For production purposes, an additional 60 similarly configured hosts were added to the environment. Later,
the hosts started reporting random QFull errors, and the aggregated performance degraded. Which two
solutions would alleviate the QFull errors and performance problems? (Choose two.)
A. Remove Selective LUN Mapping (SIM) from the 4-node FAS9000 cluster.
B. Download the latest FC HBA driver, firmware, and BIOS, and deploy them on the hosts.
C. Configure and use additional FC target HBAs in the FAS9000 cluster.
D. Reduce FC HBA gueue depth on the hosts.
Exhibit.

Dining a data mobility test on a 4-node ONTAP 9.3 cluster, the host loses direct access to its LUNs. The LUNs are hosting on node cl1-01 and are being moved to cl1-03 on a different HA pair. Referring to the exhibit, which corrective step is needed to ensure access while the volume is moved?
A. Add reporting nodes for cl1-03 and cl1-04.
B. Create additional LIFs on cl1-01 and cl1-02.
C. Create a new destination volume on cll-03.
D. Create new igroups on cl1-03 and cl1-04.
Click the Exhibit button.

You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI protocol is enabled.
Referring to the exhibit, what is needed to allow hosts to log into the iSCSI target?
A. Create new LIFs with the iSCSI data protocol.
B. Create new igroups with the host IQNs.
C. Add iSCSI to the data protocol of the existing LIFs.
D. Map LUNs to the igroups.
A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth is set to 64. The FC hosts are now experiencing random connectivity issues.
In this scenario, what would be the reason for the disconnects?
A. The FC host has a lower queue depth.
B. According to the IMT, unsupported HBA firmware is in use.
C. All of the hosts are part of the same cluster.
D. The queue depth is not consistent across the cluster.
You are provisioning storage to an ESX host that uses iSCSI.
According to NetApp best practice, which three actions accomplish this task? (Choose three.)
A. Enable the iSCSI service.
B. Bind the iSCSI ports to the software iSCSI adapter.
C. Install Virtual Storage Console (VSC) for VMware.
D. Enable BGP on the switch.
E. Configure MTU 1500 on the switch.
A customer has multiple host applications that require FC block storage. You need to gather and validate the customer's requirements for a supported NetApp solution.
Which two tools would be used to accomplish this task? (Choose two.)
A. Interoperability Matrix Tool (IMT)
B. OneCollect
C. Config Advisor
D. Hardware Universe (HWU)
A user cannot add more than one NVMe data LIF in ONTAP 9.4 on an SVM with a data protocol parameter set to nvme.
In this scenario, what is the problem?
A. The SVM data protocol should be set to FC.
B. The NVMe namespace is not created.
C. A demo license is used.
D. Only one NVMe data LIF can be configured per SVM.