Refer to the exhibit

In this scenario a Cisco engineer is building a loop-free topology where a dedicated layer of the vPC domain adjacent to the aggregation layer which also runs vPC Is used to interconnect the two data centers together. The engineer globally configures a vPC domain identifier on both vPC devices where the domain ID is the same on both peer devices. Which action successfully forms the domain?
A. Configure vPC-peer-keepalive link on both peer devices
B. Put peer device interfaces into a suspended state.
C. Enable and reuse an ISL Layer 3 trunk port channel
D. Synchronize the MAC addresses for the member ports
A company is using Cisco UCS and wants a network orchestration solution to meet these requirements:
1.
centrally manage compute and storage platforms
2.
reduce the time it takes to detect an outage
3.
easily exchange data with TAC to reduce resolution times
The company does not have in-house knowledge about scripting.
Which solution must the company choose?
A. Cisco Intersight
B. Cisco UCS Central
C. Cisco HyperFlex
D. Cisco DCNM
An engineer must design the compute portion of a data center environment. The environment includes:
1.
direct-attach Fibre Channel storage array with four 32 G Fibre Channel ports per controller
2.
Cisco UCS B-series servers equipped with Cisco UCS IOM 2408 Fabric Extenders
3.
Cisco 6454 Fabric Interconnects
The fabric interconnects connect to the LAN via 100G ports, the SAN via 32 G Fibre Channel ports, and the IOM 2408 via 10 G ports. Which storage connectivity strategy must the engineer choose?
A. UCS: Qty four 802.1q trunks from each IOM to each fabric interconnect Storage: Qty two Fibre Channel links from each SAN controller to each fabric interconnect
B. UCS: four-port back-to-back PortChannel between IOM and fabric interconnect Storage: two-port SAN-PortChannel from each SAN controller to each fabric interconnect
C. UCS: two-port PortChannel from each IOM to each fabric interconnect Storage: Qty four Fibre Channel links from each SAN controller to each fabric interconnect
D. UCS: four-port PortChannel from each IOM to each fabric interconnect Storage: four-port SAN-PortChannel from each SAN controller to each fabric interconnect